Nocturn Keyboard Calibration

Nocturn Keyboard Calibration Initial Setup



Make sure you have installed the latest version of Automap from our website.





Connecting a programmed unit and selecting calibration mode



Connect the Nocturn Keyboard to a computer. While holding octave up and down buttons down
together,turn the Nocturn Keyboard on. Keep these two buttons pressed down
until buttons 1 to 4 and button 8 is lit. The octave ‘-‘ and ‘+’ buttons will be
flashing.







This indicates that the keyboard is in calibration mode.



There are 4 features to calibrate – the pitch wheel, the mod wheel, the
aftertouch sensitivity and the keyboard length.



Calibration Order:



1) pitch wheel

2) mod wheel

3) aftertouch sensitivity

4) keyboard length



Once the calibration has been setup, this needs to be saved to the unit (this is
not automatic).



Pitch Wheel Calibration



While watching the first encoder ring move the pitch wheel through it’s full
range of travel once. This calibrates the unit. The calibration can then be
checked by moving the pitch wheel through a full range of travel a second
time.



At position 1 (pitch wheel minimum), only the first LED of LED ring 1 should
be lit
.


At position 2 (pitch wheel maximum), all 11 LEDs for LED ring 1 should be lit.



At position 3 (pitch wheel spring back to centre), the first 6 LEDs of LED ring 1
should be lit.







Mod Wheel Calibration



While watching the second encoder ring move the mod wheel through it’s full
range of travel once. This calibrates the unit. The calibration can then be
checked by moving the mod wheel through a full range of travel a second
time.



At position 1 (mod wheel maximum), all 11 LEDs for LED ring 1 should be lit.



At position 2 (pitch wheel minimum), only the first LED of LED ring 1 should
be lit.



There is no spring for the mod wheel, so the centre position is not critical and
does not need to be checked.







Aftertouch Calibration



The LEDs around encoder 3 register the aftertouch output. The 4th encoder is
used to calibrate this output and the LED ring around encoder 4 shows the
calibration value.



Press firmly and keep holding a key on the keymech (of the order of 30 N to
40). Turn encoder 4 anticlockwise until less then 11 LEDs are lit around
encoder 3. Now slowly turn encoder 3 clockwise until all 11 LEDs are lit
around encoder 3. Check 2 or 3 other keys can be pressed firmly and all 11
LEDs are lit around encoder 3. If not, turn encoder 4 clockwise slowly again
until all 11 LEDs are lit for this key.







Keyboard Length Calibration



Press both the top key and the bottom key simultaneously and release both
keys.





Save Calibration Settings



The calibration settings are not automatically saved. These must be saved to
the manually saved to the unit In order for these settings to be retained on the
unit, press button 8 on the unit.





The unit will then reboot.